Provides the operator a way to properly reboot the ATM. It is then safe to power off the ATMs peripheral devices. The systems processing engine will power off automatically. On rear-service systems, the ROP will also go blank.
Diebold Opteva 760 Manual windows#
If a customer is not in session at the time of the request, the front screen of the ATM will go to the Out-Of-Service screen and the ROP will look like the following example screen:Īfter the system successfully shuts down the Global CAT ATM and the Windows XP operating system (approximately 45-55 seconds), the front screen will go blank. Select Shutdown from the command list and confirm it. Provides the operator a way to properly shut down the ATM so that it can be powered off for hardware maintenance or replacement. If this confirmation is not responded to within the 20 seconds, the confirmation window is removed without any action. Select the Confirm button (the Y key for the ROP) to confirm the selection or the Cancel button (the N key for the ROP) to cancel the selection. When a command is selected, a confirmation window is displayed. The following commands are available from both the ROP and the OOP: The bottom line of the operator panel displays the Citibank logo on the left and the node ID on the right. This area remains blank if there are no outstanding errors or warnings.
![Diebold Opteva 760 Manual Diebold Opteva 760 Manual](https://img.yumpu.com/2512760/1/500x640/177-576-rev-1-diebold.jpg)
The next eight lines of the operator panel are reserved for any specific device errors or warnings. The second and third lines of the operator panel display the Expanded State Description and are a more detailed description of the current state of the ATM. The top line of the operator panel display is the Overall State Description, and is an abbreviated text description describing the current state of the ATM. Significant differences are noted where applicable.
![Diebold Opteva 760 Manual Diebold Opteva 760 Manual](http://www.financialequipmentsupplies.com/files/2157120/uploaded/HP6602A.jpg)
Keep in mind that there are some minor differences in the way that the operator interacts with these applications due to the differing input methods. NOTE All the instructions in this appendix apply to both the ROP and OOP because they are functionally equivalent. For security reasons, if the front fascia of the ATM is closed while the OOP is still activated, the command buttons are disabled. The Touch Screen is used for operator input and the system keyboard is not needed for most operations.Ĥ. Holding down the mode switch again returns the main display to the Hello screen (or the Out-of-Service screen if the ATM is not in Up state).ģ. Hold down the mode switch for about 2 seconds to activate the OOP on the ATMs main display. Find the mode rocker switch, located behind the fascia at the top right of the enclosure. The lock is located on the upper left fascia panel.Ģ. Insert the key and unlock and pull open the front fascia of the ATM. To activate the Onscreen Operator Panel (OOP), follow these steps:ġ. On Opteva front-service models, which have no separate display panel, the customer display is used for operator functions. The system keyboard (available inside the ATM cabinet) is used in conjunction with the ROP for performing operator functions. A Using the Operator Panel of a Diebold Opteva ATMOpteva rear-service models include a rear display panel which provides status information and facilitates diagnostic and maintenance operations (referred to as the Rear Operator Panel or ROP).